← Back to Switchgear

Medium-Voltage Vacuum Circuit Breakers

Reliable medium-voltage switching and protection: 5 kV and 15 kV class vacuum circuit breakers.

Wafr Medium-Voltage Vacuum Circuit Breakers provide reliable switching, fault interruption and protection for industrial, commercial, utility and infrastructure power-distribution systems.

The breakers use vacuum interruption technology with a stored-energy operating mechanism and are designed for installation in Wafr metal-clad switchgear or compatible medium-voltage switchgear assemblies.

Available configurations cover common Canadian 5 kV and 15 kV applications, including 4.16 kV, 12.47 kV, 13.2 kV and 13.8 kV systems.

Key Ratings

ParameterStandard Ratings
Equipment class5 kV / 15 kV
Typical system voltages4.16 / 12.47 / 13.2 / 13.8 kV
Rated maximum voltage4.76 / 15 kV
Frequency60 Hz
Phases3
Continuous current630 / 1200 / 2000 / 3000 / 4000 A
Short-circuit interrupting rating25 / 31.5 / 40 / 50 kA
15 kV-class BIL95 kV
Interrupting mediumVacuum
ConfigurationDrawout
Operating mechanismStored-energy spring
Electrical operationLocal and remote
Typical control power125 Vdc
Auxiliary contactsConfigurable
Mechanical interlockingStandard
Electrical interlockingStandard

Final breaker ratings are selected according to system voltage, continuous current, available fault current, protection requirements and switchgear configuration.

Available Configurations

Configuration

Drawout, with connected, test and disconnected positions

Operating Mechanism

Stored-energy spring

Operation

Electrically operated close and trip, local and remote

Interlocking

Positive mechanical and electrical interlocking as standard

Control Power

125 Vdc typical; configurable auxiliary contacts

Product Composition

Product Features

Key Features

  • Vacuum interruption for long electrical and mechanical life
  • Drawout construction for maintainability and isolation
  • Stored-energy spring operating mechanism
  • Electrically operated close and trip functions
  • Mechanical position indication
  • Connected, test and disconnected positions
  • Positive mechanical and electrical interlocking
  • Local and remote operation
  • Integration with numerical protection relays
  • SCADA and building-management-system integration
  • Low maintenance requirements
  • Suitable for frequent switching applications
  • Ground-and-test device provisions available
  • Canadian 60 Hz configuration

Protection & Control

Wafr circuit breakers can be integrated with modern numerical protective relays supporting ANSI protection functions including:

  • 50 — Instantaneous Overcurrent
  • 51 — Time Overcurrent
  • 50N/51N — Ground Overcurrent
  • 27 — Undervoltage
  • 59 — Overvoltage
  • 81 — Frequency
  • 46 — Negative Sequence
  • 49 — Thermal Protection
  • 50BF — Breaker Failure

Additional protection functions are available according to the application.

Standards & Certification

Wafr Medium-Voltage Vacuum Circuit Breakers and associated switchgear configurations are certified and tested to applicable Canadian and North-American requirements, including:

  • CSA C22.2 No. 31 — Switchgear Assemblies
  • IEEE C37.04 — AC High-Voltage Circuit Breaker Rating Structure
  • IEEE C37.09 — Test Procedures for AC High-Voltage Circuit Breakers
  • IEEE C37.20.2 — Metal-Clad Switchgear
  • IEEE C37.20.6 — Ground and Test Devices, where applicable
  • CSA C22.1 — Canadian Electrical Code, Part I, for installation requirements

Applications

  • Utility distribution
  • Mining
  • Oil & gas
  • Data centres
  • Industrial facilities
  • Water and wastewater facilities
  • Commercial facilities
  • Hospitals and healthcare facilities
  • Universities and institutional facilities
  • Renewable-energy facilities
  • Battery energy-storage installations
  • Generator distribution and paralleling systems

Key Features

  • Vacuum interruption for long electrical and mechanical life
  • Drawout construction for maintainability and isolation
  • Stored-energy spring operating mechanism
  • Electrically operated close and trip functions
  • Mechanical position indication
  • Connected, test and disconnected positions
  • Positive mechanical and electrical interlocking
  • Local and remote operation
  • Integration with numerical protection relays
  • SCADA and building-management-system integration
  • Low maintenance requirements
  • Suitable for frequent switching applications
  • Ground-and-test device provisions available
  • Canadian 60 Hz configuration
Let's connect

Talk to Our Team

Start with a simple general inquiry to start the conversation. Or tell Wafr what equipment you need, where it is going and when the project needs it.