Dry-Type & Cast-Coil Transformers

Safe, efficient transformation for indoor and critical facilities.

Wafr Dry-Type & Cast-Coil Transformers provide reliable power transformation without liquid insulation, making them well suited to indoor, commercial, industrial and critical-infrastructure applications.

Available technologies include ventilated dry-type, vacuum-pressure-impregnated and cast-resin/cast-coil construction.

Key Specifications

Specification

Configuration

Capacity

15 to 7,500 kVA

Phases

Single / Three-phase

Primary Voltage

Up to 35 kV

Secondary

600Y/347 · 480Y/277 · 208Y/120 V

Frequency

60 Hz

Cooling

AN / AF

Construction

Ventilated / Non-ventilated / Cast-coil

Construction

Ventilated Dry-Type

Suitable for commercial and industrial installations where economical, reliable indoor transformation is required.

VPI Transformer

Vacuum-pressure-impregnated windings provide enhanced mechanical strength and environmental resistance.

Cast-Coil Transformer

Resin-encapsulated windings provide increased resistance to moisture, contamination and demanding environmental conditions.

Key Features

  • Copper or aluminum windings
  • 80 / 115 / 150°C temperature-rise options where applicable
  • Temperature monitoring
  • Embedded winding sensors
  • Digital temperature controller
  • Forced-air cooling
  • Low-noise design
  • Electrostatic shielding
  • K-factor designs
  • Harmonic-duty designs
  • Ground shields
  • Surge protection
  • Special impedance
  • Indoor and outdoor enclosures

Ratings, Standards & Applications

Standard Ratings

ParameterAvailable Ratings
TypeDry-type / Cast-coil
PhasesSingle / Three-phase
Frequency60 Hz
Capacity15–7500 kVA
Primary voltageUp to 35 kV
Common MV systems4.16 / 12.47 / 13.2 / 13.8 / 24.9 / 34.5 kV
Secondary600Y/347 V
480Y/277 V
208Y/120 V
CoolingAN / AF
WindingsCopper / Aluminum
ConstructionVentilated / Non-ventilated / Cast-coil
InstallationIndoor / Outdoor where suitably enclosed
EfficiencyCanadian efficiency compliant

Standards & Certification

  • CSA C9 — Dry-Type Transformers
  • CAN/CSA C802.2 — Test Method and Minimum Efficiency Values for Dry-Type Transformers
  • IEEE C57.12.01 — General Requirements for Dry-Type Distribution and Power Transformers
  • Applicable IEEE transformer testing requirements
  • CSA C22.1 — Canadian Electrical Code

Applications

  • Data centres
  • Hospitals
  • Commercial buildings
  • Industrial facilities
  • Mining
  • Water treatment
  • Institutional facilities
  • Renewable energy
  • Indoor substations
  • Critical-power systems

Normal Use Conditions

Available Options

Enclosure Options

  • Type 1 indoor
  • Type 2 drip-proof
  • Type 3R outdoor
  • Project-specific enclosures