Dry-Type Distribution Transformer

Epoxy cast dry-type transformers designed for reliable, low-maintenance power distribution.

Wafr supplies dry-type distribution transformers using electrically oriented silicon steel or amorphous alloy core materials with epoxy resin cast coils. The design provides strong fire resistance, moisture resistance and insulation performance for demanding indoor and outdoor installations.

Key Specifications

Specification

Configuration

Power Rating

30 to 2,500 kVA

Primary Voltage

10 kV

Transformer Type

Epoxy Cast Dry-Type

Core Options

Electrically Oriented Silicon Steel or Amorphous Alloy

Winding

Epoxy Resin Cast

Installation

Indoor or Outdoor Configurations

Insulation

Epoxy Resin

Construction

Core

Three-phase, three-column laminated core construction using electrically oriented silicon steel or amorphous alloy core materials.

Windings

H-class film-coated flat copper wire with epoxy resin insulation, designed for moisture and corrosion resistance, low partial discharge and mechanical and thermal stability.

Clamping Structure

Frame-style clamping construction supports the transformer core and windings and provides mechanical stability under operating and short-circuit forces.

Core: A three-phase three-column laminated core is used, and the three columns are all covered with windings. The left and right magnetic flux phases are different, the core magnetic circuit is unbalanced, and the middle column magnetic circuit is shorter, which reduces the no-load current.

Winding: It is made of H-class film-coated non-woven flat copper wire and epoxy resin insulating material, which is moisture-proof and corrosion-resistant, has small partial discharge, has sufficient dynamic and thermal stability, and will not shift during operation and transportation.

Clamp: Frame structure, the clamping structure bears the clamping force, the gravity of the lifting body and the mechanical force generated when the transformer is short-circuited, ensuring the electromagnetic performance of the cold-rolled electrical steel sheet.

Key Features

  • Low-loss, low-noise design
  • Flame-retardant and self-extinguishing construction
  • Moisture and corrosion resistance
  • High mechanical strength and short-circuit resistance
  • Low partial discharge
  • Strong lightning impulse resistance
  • Compact and lightweight construction
  • Designed for installation in space-constrained load centres

Product Performance Advantages

Product Performance Advantages

  • Low loss and low noise.
  • No pollution, maintenance-free, easy to install and low overall operating cost.
  • Small size and light weight.
  • High mechanical strength, strong resistance to temperature changes and short circuit resistance.
  • Moisture-proof and corrosion-resistant, it can operate in high humidity.
  • Economical installation, can be installed in load centers without special foundation.
  • Feasibility, reliability, security, stability.
  • It has good insulation performance, small partial discharge and strong lightning impulse resistance.
  • It has good fire resistance and is refractory to flames and self-extinguishing.
  • Suitable for urban substations with dense population and narrow space.

Normal Use Conditions

  • Ambient temperature: ultra-high temperature +40°C
  • Ultra-low temperature: -25°C (outdoor dry-type transformer)
  • Ultra-low temperature: -5°C (indoor dry-type transformer)
  • Monthly average temperature: ultra-high 30°C
  • Annual average temperature: ultra-high 20°C
  • Power supply voltage waveform: should be approximately a sine wave